2020-42T-C4FLF vs 2020-42T-C2FLF vs 2020-42T-C2LF

 
PartNumber2020-42T-C4FLF2020-42T-C2FLF2020-42T-C2LF
DescriptionGas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBEGas Discharge Tubes - GDTs / Gas Plasma Arrestors 360volts Fail ShortGas Discharge Tubes / Gas Plasma Arrestors 360volts
ManufacturerBournsBournsBourns Inc.
Product CategoryGas Discharge Tubes - GDTs / Gas Plasma ArrestorsGas Discharge Tubes - GDTs / Gas Plasma ArrestorsGas Discharge Tube Arresters (GDT)
Series2020 T2020 T2020 T
Peak Pulse Current10 kA10 kA0.5 A
DC Sparkover360 V360 V360 VDC
Number of Electrodes3 Electrode3 Electrode3 Electrode
Termination StyleRadialRadialThrough Hole
Failsafe Protection Y/NFailsafe ProtectedFailsafe Protected-
Diameter7.9 mm7.9 mm13 mm
Length-13 mm15.4 mm
Minimum Operating Temperature- 40 C- 40 C-
Maximum Operating Temperature+ 90 C+ 90 C-
TechnologyGas Discharge TubesGas Discharge Tubes-
Type3 Electrode Miniature Gas Discharge Tube3 Electrode Miniature Gas Discharge Tube-
BrandBournsBourns-
Mounting StyleThrough HoleThrough Hole-
Insulation Resistance1 GOhms1 GOhms-
Product TypeGDTs - Gas Discharge Tubes / Surge ArrestersGDTs - Gas Discharge Tubes / Surge Arresters-
SubcategoryGDTs - Gas Discharge TubesGDTs - Gas Discharge Tubes-
RoHS-Y-
Packaging-TrayTray
Factory Pack Quantity-100-
Unit Weight-0.179544 oz-
Number of Poles--3
Package Case--Axial Cylinder, 3 Lead (Radial Bend)
Mounting Type--Through Hole
Tolerance---
Voltage DC Spark Over Nom--360V
Impulse Discharge Current 8 20μs--10000A (10kA)
Fail Short--No
Failsafe Protection Y N--Failsafe Not Protected
Top