PartNumber | 2026-30-C2FLF | 2026-30-C2F | 2026-30-C2 |
Description | Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 300VOLT | Gas Discharge Tubes / Gas Plasma Arrestors Sparkover100V/s 300V 3 Pole | Gas Discharge Tubes / Gas Plasma Arrestors Sparkover100V/s 300V 3 Pole |
Manufacturer | Bourns | Bourns Inc. | Bourns Inc. |
Product Category | Gas Discharge Tubes - GDTs / Gas Plasma Arrestors | Gas Discharge Tube Arresters (GDT) | Gas Discharge Tube Arresters (GDT) |
RoHS | Y | - | - |
Series | 2026 | 2026 | 2026 |
Peak Pulse Current | 40 kA | 40 kA | 40 kA |
DC Sparkover | 300 V | 300 VDC | 300 VDC |
Number of Electrodes | 3 Electrode | 3 Electrode | 3 Electrode |
Termination Style | Radial | - | - |
Failsafe Protection Y/N | Failsafe Protected | - | - |
Minimum Operating Temperature | - 40 C | - | - |
Maximum Operating Temperature | + 90 C | - | - |
Packaging | Bulk | Tube | Tube |
Technology | Gas Discharge Tubes | Gas Discharge Tube | Gas Discharge Tube |
Type | 3-Pole Gas Discharge Tube | - | - |
Brand | Bourns | - | - |
Mounting Style | Through Hole | - | - |
Insulation Resistance | 10 GOhms | - | - |
Product Type | GDTs - Gas Discharge Tubes / Surge Arresters | - | - |
Factory Pack Quantity | 100 | - | - |
Subcategory | GDTs - Gas Discharge Tubes | - | - |
Unit Weight | 0.035274 oz | - | - |
Number of Poles | - | 3 | 3 |
Package Case | - | Axial Cylinder, 3 Lead (Radial Bend) | Axial Cylinder, 3 Lead (Radial Bend) |
Mounting Type | - | Through Hole | Through Hole |
Tolerance | - | ±20% | ±20% |
Voltage DC Spark Over Nom | - | 300V | 300V |
Impulse Discharge Current 8 20μs | - | 20000A (20kA) | 20000A (20kA) |
Fail Short | - | Yes | No |
Failsafe Protection Y N | - | Failsafe Protected | Failsafe Protected |