2047-09-ALF vs 2047-09-ANI vs 2047-09

 
PartNumber2047-09-ALF2047-09-ANI2047-09
DescriptionGas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBEGas Discharge Tubes / Gas Plasma Arrestors GAS DISCHARGE TUBE
ManufacturerBournsBourns Inc.-
Product CategoryGas Discharge Tubes - GDTs / Gas Plasma ArrestorsGas Discharge Tube Arresters (GDT)-
RoHSY--
Series20472047-
Peak Pulse Current50 kA--
DC Sparkover90 V--
Number of Electrodes2 Electrode--
Termination StyleSMD/SMT--
Failsafe Protection Y/NFailsafe Not Protected--
Diameter6.5 mm--
Minimum Operating Temperature- 40 C--
Maximum Operating Temperature+ 90 C--
TechnologyGas Discharge Tubes--
Type2 Electrode High Current GDT--
BrandBourns--
Mounting StyleSMD/SMT--
Insulation Resistance1 GOhms--
Product TypeGDTs - Gas Discharge Tubes / Surge Arresters--
Factory Pack Quantity50--
SubcategoryGDTs - Gas Discharge Tubes--
Unit Weight0.258311 oz--
Packaging-Bulk-
Number of Poles-2-
Package Case-Cylinder No Lead-
Mounting Type-User Defined-
Tolerance-±20%-
Voltage DC Spark Over Nom-90V-
Impulse Discharge Current 8 20μs-40000A (40kA)-
Fail Short-No-
Top